TM 10-3930-673-20-1
41. EMERGENCY STEERING PUMP DOES NOT OPERATE (CONT).
12
KNOWN INFO
TEST OPTIONS
Hydraulic Systems OK.
Voltage test.
Is voltage present at
Gages OK.
STE/ICE-R #89.
emergency steering solenoid
Wire 10 OK.
REASON FOR QUESTION
Hydraulic pressure sensor OK.
where ground wire connects?
If voltage is not present,
Wire 91 OK.
emergency steering solenoid is
Emergency steering switch OK.
faulty.
Connector J1 OK.
Connector P1 OK.
Wire 92 OK.
Emergency steering relay OK.
POSSIBLE PROBLEMS
Emergency steering solenoid
faulty.
Replace emergency
NO
steering solenoid
(Para 8-22).
YES
KNOWN INFO
TEST OPTIONS
13
Hydraulic Systems OK.
Voltage test.
Is voltage present at
Gages OK.
STE/ICE-R #89.
Wire 10 OK.
emergency steering motor
REASON FOR QUESTION
Hydraulic pressure sensor OK.
where wire 9 connects?
If voltage is not present, wire 9 is
Wire 91 OK.
faulty.
Emergency steering switch OK.
Connector J1 OK.
Connector P1 OK.
Wire 92 OK.
Emergency steering relay OK.
Emergency steering solenoid OK.
POSSIBLE PROBLEMS
Wire 9 faulty.
Emergency steering motor faulty.
Repair wire 9 (Para
NO
8-49).
YES
2-586
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |