TM 10-3930-673-20-1
CONTINUITY TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Remove four screws and access panel.
(3) Set multimeter to ohms.
(4) Connect multimeter positive lead (+) to
circuit breaker CB1 where wire 10
connects.
(5) Connect multimeter negative lead () to
connector J1-23.
ACCESS
P
(a) If continuity is present, go to Step 3
SCREW
of this fault.
ANEL
CIRCUIT BREAKER CB1
(b) If continuity is not present, repair
wire 10 and/or connector J1
(Para 8-48).
(6) Install access panel and four screws.
WIRE 10
CONTINUITY TEST
HYDRAULIC
P
(1) Disconnect negative battery cable from
W1RE
I
S ESSURE
R
negative side of battery (Para 8-42).
91
10
0
ENSOR
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
hydraulic pressure sensor where wire
10 connects.
NC
(4) Connect multimeter negative lead () to
C
NO
connector P1-23.
(a) If continuity is present, go to Step 4
of this fault.
(b) If continuity is not present, repair
P1-23
wire 10 and/or connector P1
(Para 8-49).
CONNECTOR P1
J1-23
CONNECTOR J1
TR01554
2-577
|