TM 10-3930-673-20-1
l
CONTINUITY TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Disconnect connector J1 from
connector P1.
(3) Set multimeter to ohms.
(4) Connect multimeter positive lead (+) to
wire 17 where wire 17 connects to oil
pressure gage.
(5) Connect multimeter negative lead () to
connector J1-12.
WIRE 17
(a) If continuity is present, go to Step 6
of this fault.
(b) If continuity is not present, repair
wire 17 or connector J1
(Para 8-48).
(6) Install instrument panel and four
screws.
TRANSDUCER
WIRE 17
CONTINUITY TEST
(1) Disconnect connector J1 from
connector P1.
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
wire 17 where wire 17 connects to
engine oil pressure transducer.
(4) Connect multimeter negative lead () to
J1-12
connector P1-12.
(a) If continuity is present, replace oil
P1-12
pressure transducer (Para 8-35).
(b) If continuity is not present, repair
wire 17 or connector P1
(Para 8-49).
(5) Connect negative battery cable to
negative side of battery.
CONNECTOR
J
(6) Install battery cover (Para 8-42).
1
CONNECTOR P1
CONNECTOR
J
1
CONNECTOR P1
TR01502