Remove rings bracelets watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on
equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock.
Battery acid is harmful to skin and eyes. Always wear eye protection when working with batteries.
VOLTAGE TEST
INSPRUMENT
T
ANEL
SCREW
(1) Remove battery cover (Para 8-42).
TEMPERATURE
G
(2) Disconnect negative battery cable from
AGE
negative side of battery (Para 8-42).
(3) Remove four screws from right-hand
instrument panel.
(4) Set multimeter to volts dc.
(5) Lift right-hand instrument panel out to
reach temperature gage.
(6) Connect multimeter positive lead (+) to
temp gage where wire 10 connects.
(7) Connect multimeter negative lead () to
known good ground.
(8) Connect negative battery cable to
negative side of battery (Para 8-42).
(9) Turn engine start switch to ON position,
BUT DO NOT START ENGINE
(TM 10-3930-673-10).
(a) If 24 vdc is present, go to Step 3 of
this fault.
(b) If 24 vdc is not present, repair
wire 10 (Para 8-48).
(10) Turn engine start switch to OFF
position (TM 10-3930-673-10).
(11) Disconnect negative battery cable from
ENGINE START
S
negative side of battery (Para 8-42).
WITCH
WIRE 10
TR01534
2-553

Privacy Statement - Press Release - Copyright Information. - Contact Us