TM 10-3930-673-20-1
CONTINUITY TEST
(1) Disconnect connector J1 from
connector P1.
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
wire 12 where wire 12 connects to fuel
gage.
(4) Connect multimeter negative lead () to
connector J1-16.
WIRE 12
(a) If continuity is present, go to Step 6
of this fault.
(b) If continuity is not present, repair
wire 12 or connector J1
(Para 8-48).
(5) Connect connector J1 to connector P1.
TRANSDUCER
WIRE 12
CONTINUITY TEST
(1) Disconnect connector J1 from
connector P1.
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
wire 12 where wire 12 connects to fuel
level transducer.
(4) Connect multimeter negative lead () to
connector P1-16.
(a) If continuity is present, replace fuel
level transducer (Para 8-38).
J1-16
(b) If continuity is not present, repair
P1-16
wire 12 or connector P1
(Para 8-49).
(5) Connect connector J1 to connector P1.
(6) Install instrument panel and four
screws.
(7) Connect negative battery cable to
CONNECTOR
J
negative side of battery (Para 8-42).
1
(8) Install battery cover (Para 8-42).
CONNECTOR P1
CONNECTOR
J
1
CONNECTOR P1
TR01552
2-549
|