37. FUEL GAGE DOES NOT OPERATE (CONT).
3
KNOWN INFO
TEST OPTIONS
Low fuel.
Voltage test.
Is voltage present at fuel gage
Wire 10 OK.
STE/ICE-R #89.
where wire 12 connects?
POSSIBLE PROBLEMS
REASON FOR QUESTION
Fuel gage faulty.
If voltage is not present, fuel gage
Wire 12 faulty.
faulty.
Connector J1 faulty.
Connector P1 faulty.
Fuel level transducer faulty.
Replace fuel gage
NO
(Para 8-6).
YES
4
KNOWN INFO
TEST OPTIONS
Low fuel.
Voltage test.
Is voltage present at fuel level
Wire 10 OK.
STE/ICE-R #89.
transducer where wire 12
Fuel gage OK.
REASON FOR QUESTION
connects?
POSSIBLE PROBLEMS
This question eliminates possible
Wire 12 faulty.
problems and determines where
Connector J1 faulty.
troubleshooting continues.
Connector P1 faulty.
Fuel level transducer faulty.
Go to Step 5 of this
NO
fault.
YES
Repair fuel level
transducer
(Para 8-38).