Click here to make tpub.com your Home Page

Page Title: NONE OF THE GAGES OPERATE - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-1
34. NONE OF THE GAGES OPERATE (CONT).
5
KNOWN INFO
TEST OPTIONS
Gages do not operate.
Voltage test.
Is 24 vdc present on wire 3
Battery OK.
STE/ICE-R #89.
where wire 3 connects to run
Battery cable OK.
REASON FOR QUESTION
relay?
Wire 9 OK.
If voltage is not present, run relay
Connector P2 OK.
faulty.
Connector J2 OK.
Circuit breaker CB6 OK.
Wire 1 OK.
POSSIBLE PROBLEMS
Run relay faulty.
Wire 3 faulty.
Circuit breaker CB1 faulty.
Wire 10 faulty.
Fuel gage faulty.
Replace run relay
NO
Wire 12 faulty.
(Para 8-23).
Connector J1 faulty.
Connector P1 faulty.
Fuel level transducer faulty.
YES
6
KNOWN INFO
TEST OPTIONS
Gages do not operate.
Voltage test.
Is 24 vdc present on wire 3
Battery OK.
STE/ICE-R #89.
where wire 3 connects to
Battery cable OK.
REASON FOR QUESTION
circuit breaker CB1?
Wire 9 OK.
If voltage is not present, wire 3
Connector P2 OK.
faulty.
Connector J2 OK.
Circuit breaker CB6 OK.
Wire 1 OK.
Run relay OK.
POSSIBLE PROBLEMS
Wire 3 faulty.
Circuit breaker CB1 faulty.
Wire 10 faulty.
Repair wire 3 (Para
NO
8-48).
YES
2-512

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business