TM 10-3930-673-20-1
PANEL
CONTINUITY TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Set multimeter to ohms.
(3) Disconnect connector J1 from
connector P1.
(4) Remove four screws from access
panel.
(5) Connect multimeter positive lead (+) to
wire 50 where wire 50 connects to
circuit breaker CB6.
(6) Connect multimeter negative lead () to
connector J1-37.
(a) If continuity is present, go to
Step 16 of this fault.
(b) If continuity is not present, repair
SCREW
wire 50 and/or connector J1
(Para 8-48).
WIRE 50
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Disconnect connector J4 from
J1-37
connector P4.
(3) Connect multimeter positive lead (+) to
J1-36
connector P1-37 where wire 50
connects.
J1-35
(4) Connect multimeter negative lead () to
P1-37
connector J4-N.
P1-36
(a) If continuity is present, go to
Step 17 of this fault.
(b) If continuity is not present, repair
P1-35
CONNECTOR
J
wire 50 and/or connectors P1, J4
1
(Para 8-49), (Para 8-50).
CONNECTOR P1
CONNECTOR
J
1
CONNECTOR
P
J4-N
1
J4-R
J4-P
CONNECTOR
P
CONNECTOR J4
4
TR01755
2-485
|