TM 10-3930-673-20-1
Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on
equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock.
Battery acid is harmful to skin and eyes. Always wear eye protection when working with batteries.
CONTINUITY TEST
ENGINE
START
(1) Remove indicator light from socket.
SWITCH
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
center conductor of indicator light.
(4) Connect multimeter negative lead () to
outside conductor of indicator light.
(a) If continuity is present, go to Step 3
of this fault.
(b) If continuity is not present, replace
lamp (Para 8-9).
INDICATOR
LIGHT
CENTER
OUTSIDE
CONDUCTOR
CONDUCTOR
VOLTAGE TEST
(1) Remove four screws from left-hand
LIGHT
instrument panel.
SOCKET
(2) Raise panel out to reach auto-level
light socket.
(3) Disconnect negative battery cable from
WIRE 50
negative side of battery (Para 8-42).
(4) Set multimeter to dc.
(5) Connect multimeter positive lead (+) to
wire 50 where wire 50 connects to
socket.
(6) Connect multimeter negative lead () to
known good ground.
(7) Connect negative battery cable (1) to
negative side of battery (2) (Para 8-42).
WIRE 59
(8) Turn engine start switch to ON position,
BUT DO NOT START ENGINE
(TM 10-3930-673-10).
(9) Turn auto-level switch to ON
(TM 10-3930-673-10).
(a) If voltage is present, go to Step 4
TR01748
of this fault.
(b) If voltage is not present, repair
wire 50 (Para 8-48).
(10) Turn auto-level switch OFF
(TM 10-3930-673-10).
(11) Turn engine start switch to OFF
position (TM 10-3930-673-10).
2-471
|