TM 10-3930-673-20-1
CONTINUITY TEST
WIRE 30
(1) Disconnect negative battery cable from
negative side of battery (Para 8-44).
WASHER SWITCH
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
wire 30 where wire 30 connects to
circuit breaker CB3.
(4) Connect multimeter negative lead () to
wire 30 where wire 30 connects to
washer switch.
(a) If continuity is present, repair
ground wire.
(b) If continuity is not present, repair
wire 30.
(5) Install access panel and four screws.
CIRCUIT BREAKER CB3
WIRE 9
CONTINUITY TEST
WIRE 30
(1) Disconnect negative battery cable from
negative side of battery (Para 8-44).
(2) Disconnect connector J2 from
connector P2.
(3) Set multimeter to ohms.
(4) Connect multimeter positive lead (+) to
wire 9 where wire 9 connects to circuit
breaker CB6.
(5) Connect multimeter negative lead () to
connector J2-1.
CIRCUIT BREAKER CB6
(a) If continuity is present, go to Step 5
of this fault.
(b) If continuity is not present, repair
wire 9 or connector J2 (Para 8-48).
J2-1
CONNECTOR J2
CONNECTOR
J
2
CONNECTOR P2
TR01163
2-433
|