TM 10-3930-673-20-1
VOLTAGE TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-44).
ACCESS
P
(2) Remove four screws and access panel.
ANEL
(3) Set multimeter to volts dc.
(4) Connect multimeter positive lead (+) to
wire 9 where wire 9 connects to circuit
breaker CB6.
(5) Connect multimeter negative lead () to
known good ground.
(6) Connect negative battery cable to
negative side of battery (Para 8-44).
(a) If 24 vdc is present, go to Step 5 of
this fault.
(b) If 24 vdc is not present, go to
Step 11 of this fault.
(7) Disconnect negative battery cable from
negative side of battery (Para 8-44).
SCREW
VOLTAGE TEST
WIRE 9
(1) Set multimeter to volts dc.
(2) Connect multimeter positive lead (+) to
wire 1 where wire 1 connects to circuit
breaker CB6.
(3) Connect multimeter negative lead () to
known good ground.
(4) Connect negative battery cable to
negative side of battery (Para 8-44).
(a) If 24 vdc is present, go to Step 6 of
this fault.
CIRCUIT BREAKER CB6
WIRE 1
(b) If 24 vdc is not present, replace
circuit breaker CB6.
TR01160
(5) Disconnect negative battery cable from
negative side of battery (Para 8-44).
2-427
|