TM 10-3930-673-20-1
VOLTAGE TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-44).
(2) Set multimeter to volts dc.
(3) Connect multimeter positive lead (+) to
starter motor solenoid where positive
battery cable connects.
(4) Connect multimeter negative lead () to
known good ground.
B
POSITIVE
(5) Connect negative battery cable to
CATTERY
negative side of battery (Para 8-44).
ABLE
(a) If 24 vdc is present, go to Step 4 of
this fault.
(b) If 24 vdc is not present, repair
battery cable (Para 8-42).
(6) Disconnect negative battery cable from
negative side of battery (Para 8-44).
STARTER SOLENOID
P2-1
VOLTAGE TEST
(1) Disconnect connector J2 from
connector P2.
(2) Set multimeter to volts dc.
CONNECTOR P2
(3) Connect multimeter positive lead (+) to
connector P2-1.
(4) Connect multimeter negative lead () to
known good ground.
CONNECTOR
J
(5) Connect negative battery cable to
2
negative side of battery (Para 8-44).
CONNECTOR P2
(a) If 24 vdc is present, go to Step 4 of
this fault.
(b) If 24 vdc is not present, go to
Step 12 of this fault.
(6) Disconnect negative battery cable from
negative side of battery (Para 8-44).
(7) Connect connector J2 to connector P2.
TR01159
2-425
|