TM 10-3930-673-20-1
LOW OIL PRESSURE
WIRE 16
INDICATOR LIGHT
SOCKET
WIRE 10
RESISTANCE CHECK
RESISTOR
COVER
(1) Attach multimeter positive lead (+) to
resistor at circuit breaker side.
LOW OIL
(2) Attach multimeter negative lead () to
PRESSURE
resistor at light side.
INDICATOR
(a) If 1500 ohms resistance is
SCREW
measured, replace wire 10
(Para 8-48).
PANEL
(b) If 1500 ohms resistance is not
measured, replace resistor
(Para 8-9).
TR01135
2-401
|