TM 10-3930-673-20-1
22. HIGH WATER TEMP INDICATOR LIGHT DOES NOT OPERATE (CONT).
6
KNOWN INFO
TEST OPTIONS
High water temp.
Continuity test.
Are 1500 ohms present
Other gages work.
STE/ICE-R #89.
12 vdc not measured at socket.
across resistor?
REASON FOR QUESTION
POSSIBLE PROBLEMS
If 1500 ohms are not measured,
Resistor faulty.
resistor is faulty.
Wire 10 faulty.
Replace resistor
NO
(Para 8-9).
YES
Repair or replace
wire 10 (Para 8-48).