Click here to make tpub.com your Home Page

Page Title: HIGH WATER TEMP INDICATOR LIGHT DOES NOT OPERATE - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-1
CONTINUITY CHECK
(1) Set multimeter to ohms.
(2) Connect multimeter positive lead (+) to
center conductor of bulb.
(3) Connect multimeter negative lead () to
bulb ground.
(a) If continuity is present, go to Step 3
of this fault.
CENTER
(b) If continuity is not present, replace
lens/bulb (Para 8-9).
CONDUCTOR
BULB GROUND
HIGH WATER TEMP
INDICATOR
OUTSIDE
CONDUCTOR
VOLTAGE TEST
(1) Set multimeter to ohms.
(2) Connect multimeter positive lead (+) to
outside conductor of high water temp
indicator.
(3) Connect multimeter negative lead () to
known good ground.
(a) If continuity is present, replace
lens/bulb (Para 8-9).
(b) If continuity is not present, go to
Step 4 of this fault.
TR01602
2-389

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business