VOLTAGE TEST
(1) Set multimeter to volts dc.
(2) Connect multimeter positive lead (+) to
circuit breaker CB4 where wire 3
connects.
(3) Connect multimeter negative lead () to
known good ground.
(4) Connect negative battery cable to
negative side of battery (Para 8-42).
(5) Turn engine start switch to ON position,
BUT DO NOT START ENGINE
(TM 10-3930-673-10).
(a) If 24 vdc is present, go to Step 9 of
this fault.
(b) If 24 vdc is not present, repair
wire 3 (Para 8-48).
(6) Turn engine start switch to OFF
position, (TM 10-3930-673-10).
(7) Disconnect negative battery cable from
negative side of battery (Para 8-42).
VOLTAGE TEST
(1) Set multimeter to volts dc.
WIRE 40
(2) Connect multimeter positive lead (+) to
WIRE 3
circuit breaker CB4 where wire 40
connects.
(3) Connect multimeter negative lead () to
known good ground.
(4) Connect negative battery cable to
negative side of battery (Para 8-42).
(5) Turn engine start switch to ON position,
BUT DO NOT START ENGINE
(TM 10-3930-673-10).
(a) If 24 vdc is present, go to Step 10
of this fault.
CIRCUIT BREAKER CB4
(b) If 24 vdc is not present, replace
TR01645
circuit breaker CB4 (Para 8-11).
(6) Turn engine start switch to OFF
position, (TM 10-3930-673-10).
(7) Disconnect negative battery cable from
negative side of battery (Para 8-42).
2-353