TM 10-3930-673-20-1
BULB
CONTINUITY TEST
(1) Disconnect ground female connector
from male ground connector.
SOCKET
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
ground outside conductor at blackout
drive light socket.
(4) Connect multimeter negative lead () to
ground cable.
(a) If continuity is present, replace
bulb (Para 8-32).
(b) If continuity is not present, repair
wire 2 (Para 8-49) or replace
blackout brake light socket
CONNECTOR
(Para 8-32).
D LACKOUT
B
RIVE LIGHT
P2-1
CONTINUITY TEST
(1) Set multimeter to ohms.
CONNECTOR P2
(2) Disconnect connector J2 from
connector P2.
(3) Connect multimeter positive lead (+) to
wire 9 at starter motor solenoid.
CONNECTOR
J
(4) Connect multimeter negative lead () to
2
connector P2-1.
CONNECTOR P2
(a) If continuity is present, go to
Step 16 of this fault.
(b) If continuity is not present, repair
wire 9 or connector P2 (Para 8-49).
WIRE 9
STARTER SOLENOID
TR01672
2-341