TM 10-3930-673-20-1
14. FRONT FLOODLIGHT (OR FORWARD) DOES NOT OPERATE (CONT).
8
KNOWN INFO
TEST OPTIONS
Ground OK.
Voltage test.
Is 24 vdc present at run relay
Connector P2 OK.
STE/ICE-R #89.
K1 where wire 1 connects?
Connector J2 OK.
REASON FOR QUESTION
Wire 9 OK.
If voltage is not present, wire 1
Circuit breaker CB6 OK.
faulty.
POSSIBLE PROBLEMS
Wire 1 faulty.
Run relay K1 faulty.
Wire 3 faulty.
Relay K2 faulty.
Wire 5 faulty.
Circuit breaker CB7 faulty.
Wire 70 faulty.
Front floodlight switch faulty.
Repair wire 1
NO
(Para 8-48).
YES
KNOWN INFO
TEST OPTIONS
9
Ground OK.
Voltage test.
Is 24 vdc present at run relay
Connector P2 OK.
STE/ICE-R #89.
Connector J2 OK.
K1 where wire 3 connects?
REASON FOR QUESTION
Wire 9 OK.
If voltage is not present, run relay
Circuit breaker CB6 OK.
K1 faulty.
Wire 1 OK.
POSSIBLE PROBLEMS
Run relay K1 faulty.
Wire 3 faulty.
Relay K2 faulty.
Wire 5 faulty.
Circuit breaker CB7 faulty.
Wire 70 faulty.
Front floodlight switch faulty.
Replace run relay
NO
K1 (Para 8-23).
YES
2-252
|