VOLTAGE TEST
ACCESS
P
ANEL
(1) Set multimeter to volts dc.
(2) Connect multimeter positive lead (+) to
male connector for wire 70.
(3) Connect multimeter negative lead () to
known good ground.
(4) Connect negative batter cable from
negative side of battery (Para 8-44).
(5) Turn engine start switch to ON position,
BUT DO NOT START ENGINE
(TM 10-3930-673-10).
(a) If 24 vdc is present, repair wire 70
and/or female connector for
wire 70 (Para 8-48).
(b) If 24 vdc is not present, repair
wire 70 and/or male connector for
wire 70 (Para 8-48).
SCREW
(6) Turn engine start switch to OFF
position (TM 10-3930-673-10).
(7) Install access panel and four screws to
secure access panel.
(8) Install battery cover (Para 8-42).
C
FEMALE
W NNECTOR
O
IRE 70
C
MALE
W NNECTOR
O
IRE 70
TR01081