13. ALL FLOODLIGHTS DO NOT OPERATE (CONT).
4
KNOWN INFO
TEST OPTIONS
Ground OK.
Voltage test.
Is 24 vdc present at circuit
Connector P2 OK.
STE/ICE-R #89.
breaker CB6 where wire 9
POSSIBLE PROBLEMS
REASON FOR QUESTION
connects?
Connector J2 faulty.
If voltage is not present, wire 9
Wire 9 faulty.
faulty or connector J2
Circuit breaker CB6 faulty.
(Para 8-48).
Wire 1 faulty.
Run Relay K1 faulty.
Wire 3 faulty.
Relay K2 faulty.
Wire 5 faulty.
Circuit breaker CB7 faulty.
Wire 70 faulty.
Repair wire 9 or
NO
connector J2
(Para 8-48).
YES
5
KNOWN INFO
TEST OPTIONS
Ground OK.
Voltage test.
Is 24 vdc present at circuit
Connector P2 OK.
STE/ICE-R #89.
breaker CB6 where wire 1
Connector J2 OK.
REASON FOR QUESTION
connects?
Wire 9 OK.
If voltage is not present, circuit
POSSIBLE PROBLEMS
breaker CB6 faulty.
Circuit breaker CB6 faulty.
Wire 1 faulty.
Run Relay K1 faulty.
Wire 3 faulty.
Relay K2 faulty.
Wire 5 faulty.
Circuit breaker CB7 faulty.
Wire 70 faulty.
Replace circuit
NO
breaker CB6
(Para 8-11).
YES