TM 10-3930-673-20-1
Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on
equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock.
Battery acid is harmful to skin and eyes. Always wear eye protection when working with batteries.
NEGATIVE
B
ACTERY
T
ABLE
BATTERY
VOLTAGE TEST
(1) Remove battery cover (Para 8-42).
(2) Disconnect negative battery cable from
negative side of battery (Para 8-44).
(3) Set multimeter to volts dc.
(4) Connect multimeter positive lead (+) to
starting motor solenoid where wire 9
connects.
(5) Connect multimeter negative lead () to
WIRE 9
known good ground.
(6) Connect negative battery cable to
negative side of battery (Para 8-44).
(a) If 24 vdc is present, go to Step 3 of
this fault.
(b) If 24 vdc is not present, go to
Step 2 of this fault.
(7) Disconnect negative battery cable from
negative side of battery (Para 8-44).
STARTER SOLENOID
TR01075
2-229
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |