TM 10-3930-673-20-1
CONTINUITY TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
J1-9
P1-9
(2) Set multimeter to ohms.
(3) Disconnect connector J1 from
connector P1.
(4) Connect multimeter positive lead (+) to
turn signal switch wire 27.
(5) Connect multimeter negative lead () to
connector J1-9.
(a) If continuity is present, go to Step 7
of this fault.
CONNECTOR J1
(b) If continuity is not present, repair
CONNECTOR P1
connector J1 or wire 27
(Para 8-48).
CONTINUITY TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
turn signal socket center conductor.
(4) Connect multimeter negative lead () to
connector J1-9.
(a) If continuity is present, replace
SREAR TURN
FRONT TURN
S
bulb (Para 8-33).
IGNAL BULB
IGNAL BULB
(b) If continuity is not present, repair
connector P1 or wire 27
(Para 8-49).
(5) Connect connector J1 to connector P1.
(6) Install four screws to secure access
C
CENTER
C
CENTER
panel.
ONDUCTOR
ONDUCTOR
(7) Connect negative battery cable to
negative side of battery (Para 8-42).
C OUTSIDE
C OUTSIDE
(8) Install battery cover (Para 8-42).
ONDUCTOR
G
ONDUCTOR
G
ROUND
ROUND
TR01720
2-219
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |