TM 10-3930-673-20-1
VOLTAGE TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Set multimeter to volts dc.
(3) Connect multimeter positive lead (+) to
connector P2-1.
(4) Connect multimeter negative lead () to
known good ground.
(5) Connect negative battery cable from
CONNECTOR P2
negative side of battery (Para 8-42).
(a) If 24 vdc is present, go to Step 5 of
this fault.
(b) If 24 vdc is not present, repair
wire 9 and/or connector P2
(Para 8-49).
(6) Disconnect negative battery cable from
negative side of battery (Para 8-42).
P2-1
CONNECTOR J2
ACCESS
P
ANEL
VOLTAGE TEST
(1) Remove four screws and access panel.
(2) Set multimeter to volts dc.
(3) Connect multimeter positive lead (+) to
circuit breaker CB6 where wire 9
connects.
(4) Connect multimeter negative lead () to
known good ground.
SCREW
(5) Connect negative battery cable to
negative side of battery (Para 8-42).
(a) If 24 vdc is present, go to Step 6 of
this fault.
(b) If 24 vdc is not present, repair
wire 9 and/or connector J2
(Para 8-48).
(6) Disconnect negative battery cable from
negative side of battery (Para 8-42).
WIRE 9
CIRCUIT BREAKER CB6TR01723
2-201
|