TM 10-3930-673-20-1
CONTINUITY TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
outside conductor at faulty turn signal.
(4) Connect multimeter negative lead () to
turn signal ground.
(a) If continuity is present, replace
GROUND
bulb (Para 8-33).
(b) If continuity is not present, repair
ground wire (Para 8-49).
S TURN
S IGNAL
OUTSIDE
C
OCKET
ONDUCTOR
VOLTAGE TEST
BACTERY
T
ABLE
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
WIRE 9
(2) Set multimeter to volts dc.
(3) Connect multimeter positive lead (+) to
starting motor solenoid where battery
cable connects.
(4) Connect multimeter negative lead () to
known good ground.
(5) Connect negative battery cable to
negative side of battery (Para 8-42).
(a) If 24 vdc is present, go to Step 4 of
this fault.
(b) If 24 vdc is not present, go to
service battery cable (Para 8-42).
(6) Disconnect negative battery cable from
STARTER SOLENOID
negative side of battery (Para 8-42).
TR01722
2-199
|