7. STOPLIGHT(S) DO NOT OPERATE (CONT).
19
KNOWN INFO
TEST OPTIONS
Bulb OK.
Continuity test.
Is continuity present between
Connector P2 OK.
STE/ICE-R #88.
Connector J2 OK.
circuit breaker CB6 and
REASON FOR QUESTION
Circuit breaker CB6 OK.
connector J2?
If continuity is not present, repair
Wire 1 OK.
wire 9 or connector J2
Run relay OK.
(Para 8-48).
Wire 3 OK.
Circuit breaker CB4 OK.
Wire 40 OK.
Wire 41 OK.
Brake switch OK.
Blackout light switch OK.
Wire 42 OK.
Wire 43 OK.
Repair wire 9 or
Connector J1 OK.
NO
connector J2
Connector P1 OK.
(Para 8-48).
Socket(s) OK.
Connector P2 OK.
POSSIBLE PROBLEMS
YES
Wire 9 faulty.
Connector J2 faulty.
Service or replace
battery (Para 8-42).