7. STOPLIGHT(S) DO NOT OPERATE (CONT).
4
KNOWN INFO
TEST OPTIONS
Bulbs OK.
Voltage test.
Is 24 vdc present at circuit
STE/ICE-R #89.
POSSIBLE PROBLEMS
breaker CB6 where wire 9
REASON FOR QUESTION
Connector P2 faulty.
connects?
Connector J2 faulty.
This question eliminates possible
Wire 9 faulty.
problems and determines where
Circuit breaker CB6 faulty.
troubleshooting continues.
Wire 1 faulty
Run relay faulty.
Wire 3 faulty.
Circuit breaker CB4 faulty.
Wire 40 faulty.
Blackout light switch faulty.
Wire 41 faulty.
Brake switch faulty.
Go to Step 18 of
NO
Wire 42 faulty.
this fault.
Wire 43 faulty.
Connector J1 faulty.
Connector P1 faulty.
YES
Socket(s) faulty.
5
KNOWN INFO
TEST OPTIONS
Bulbs OK.
Voltage test.
Is 24 vdc present at circuit
Connector P2 OK.
STE/ICE-R #89.
breaker CB6 where wire 1
Connector J2 OK.
REASON FOR QUESTION
connects?
POSSIBLE PROBLEMS
If 24 vdc is not present, circuit
Wire 9 faulty.
breaker CB6 faulty.
Circuit breaker CB6 faulty.
Wire 1 faulty
Run relay faulty.
Wire 3 faulty.
Circuit breaker CB4 faulty.
Wire 40 faulty.
Blackout light switch faulty.
Wire 41 faulty.
Brake switch faulty.
Replace circuit
NO
Wire 42 faulty.
breaker CB6
Wire 43 faulty.
(Para 8-11).
Connector J1 faulty.
Connector P1 faulty.
YES
Socket(s) faulty.