TM 10-3930-673-20-1
HEADLIGHT
CONTINUITY TEST
(1) Remove bulb from faulty headlight
(Para 8-31).
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
male connector.
(4) Connect multimeter negative lead () to
other male connector.
(a) If continuity is present, go to Step 2
BULB
of this fault.
(b) If continuity is not present, replace
bulb (Para 8-31).
MALE
C
ONNECTOR
2-121