TM 10-3930-673-20-1
5. INSTRUMENT PANEL GAGE LIGHTS DO NOT OPERATE (CONT).
KNOWN INFO
TEST OPTIONS
11
Bulb(s) OK.
Voltage Test.
Is 24 vdc present at female
Connector P2 OK.
STE/ICE-R #89
Connector J2 OK.
connector where wire 13
REASON FOR QUESTION
Wire 9 OK.
connects?
This question eliminates possible
Circuit breaker CB6 OK.
problems and determines where
Wire 1 OK.
troubleshooting continues.
Run relay OK.
Wire 3 OK.
Circuit breaker CB4 OK.
Wire 40 OK.
POSSIBLE PROBLEMS
Blackout light switch faulty.
Auxiliary light switch faulty.
Wire 13 faulty.
Go to Step 12 of
Connector J1 faulty.
NO
this fault.
Connector P1 faulty.
Socket(s) faulty.
YES
Go to Step 13 of
this fault.
2-112
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |