Click here to make tpub.com your Home Page

Page Title: INSTRUMENT PANEL GAGE LIGHTS DO NOT OPERATE - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-1
5. INSTRUMENT PANEL GAGE LIGHTS DO NOT OPERATE (CONT).
KNOWN INFO
TEST OPTIONS
11
Bulb(s) OK.
Voltage Test.
Is 24 vdc present at female
Connector P2 OK.
STE/ICE-R #89
Connector J2 OK.
connector where wire 13
REASON FOR QUESTION
Wire 9 OK.
connects?
This question eliminates possible
Circuit breaker CB6 OK.
problems and determines where
Wire 1 OK.
troubleshooting continues.
Run relay OK.
Wire 3 OK.
Circuit breaker CB4 OK.
Wire 40 OK.
POSSIBLE PROBLEMS
Blackout light switch faulty.
Auxiliary light switch faulty.
Wire 13 faulty.
Go to Step 12 of
Connector J1 faulty.
NO
this fault.
Connector P1 faulty.
Socket(s) faulty.
YES
Go to Step 13 of
this fault.
2-112

Privacy Statement - Press Release - Copyright Information. - Contact Us