Click here to make tpub.com your Home Page

Page Title: CAB DEFROSTER FAN(S) DO NOT OPERATE - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-1
VOLTAGE TEST
(1) Set multimeter to volts dc.
(2) Connect multimeter positive (+) lead to
relay K1 where wire 1 connects.
(3) Connect multimeter negative () lead to
known good ground.
(4) Connect negative battery cable to
negative side of battery (Para 8-44).
(a) If 24 vdc is present, replace relay
K1 (Para 8-23).
(b) If 24 vdc is not present, go to
Step 7 of this fault.
(5) Disconnect negative battery cable
(Para 8-44).
WIRE 1
B CIRCUIT
REAKER
C
B6
VOLTAGE TEST
(1) Set multimeter to volts dc.
(2) Connect multimeter positive (+) lead to
circuit breaker CB6 where wire 1
connects.
(3) Connect multimeter negative () lead to
known good ground.
(4) Connect negative battery cable to
negative side of battery (Para 8-44).
(a) If 24 vdc is present, repair faulty
wire 1 (Para 8-48).
(b) If 24 vdc is not present, go to
Step 8 of this fault.
(5) Disconnect negative battery cable
(Para 8-44).
WIRE 1
TR01090
2-93

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business