VOLTAGE TEST
P2-1
(1) Disconnect connector J2 from
connector P2.
(2) Set multimeter to volts dc.
(3) Connect multimeter positive (+) lead to
connector P2-1.
(4) Connect multimeter negative () lead to
CONNECTOR P2
known good ground.
(5) Connect negative battery cable to
negative side of battery (Para 8-44).
(a) If 24 vdc is present, go to Step 19
CONNECTOR
J
of this fault.
2
(b) If 24 vdc is not present, repair
CONNECTOR P2
connector P2 or wire 9 (Para 8-49).
(6) Connect connector J2 to connector P2.
VOLTAGE TEST
(1) Set multimeter to volts dc.
(2) Connect multimeter positive (+) lead to
WIRE 9
wire 9 where wire 9 connects to starter
motor solenoid.
(3) Connect multimeter negative () lead to
known good ground.
(4) Connect negative battery cable to
negative side of battery (Para 8-44).
(a) If 24 vdc is present, go to Step 20
of this fault.
(b) If 24 vdc is not present, service or
replace battery cable (Para 8-44).
(5) Disconnect negative battery cable
(Para 8-44).
STARTER SOLENOID
TR01100