TM 10-3930-673-20-1
HORN
CONTINUITY TEST
CONNECTOR H1
(1) Disconnect connector H1 from horn.
(2) Set multimeter to ohms.
(3) Connect multimeter positive (+) lead to
wire 2 at horn.
(4) Connect multimeter negative () lead to
negative battery cable.
(a) If continuity is not present, go to
Step 13 of this fault.
WIRE 2
(b) If continuity is present, replace
horn (Para 8-41).
NEGATIVE
B
ACTERY
T
ABLE
CONTINUITY TEST
(1) Disconnect connector J2 from
connector P2.
(2) Set multimeter to ohms.
(3) Connect multimeter positive (+) lead to
wire 2 at horn connector H1.
(4) Connect multimeter negative () lead to
connector P2-2.
P2-2
(a) If continuity is not present, repair
wire 2 (Para 8-49).
(b) If continuity is present, go to
Step 14 of this fault.
CONNECTOR P2
CONNECTOR
J
2
CONNECTOR P2
TR00953
2-59
|