TM 10-3930-673-20-1
VOLTAGE TEST
J2-1
(1) Disconnect connector J2 from
connector P2.
(2) Set multimeter to volts dc.
(3) Connect multimeter positive (+) lead to
connector J2-1.
(4) Connect multimeter negative () lead to
CONNECTOR J2
known good ground.
(5) Connect negative battery cable
(Para 8-44).
(a) If 24 vdc is not present, go to
CONNECTOR
J
Step 11 of this fault.
2
(b) If 24 vdc is present, go to Step 15
of this fault.
CONNECTOR P2
(6) Disconnect negative battery cable
(Para 8-44).
VOLTAGE TEST
(1) Set multimeter to volts dc.
(2) Connect multimeter positive (+) to
WIRE 9
starting motor solenoid where wire 9
connects.
(3) Connect multimeter negative () to
known good ground.
(4) Connect negative battery cable
(Para 8-44).
(a) If 24 vdc is not present, go to
Step 13 of this fault.
(b) If 24 vdc is present, go to Step 16
of this fault.
(5) Disconnect negative battery cable
(Para 8-44).
STARTER SOLENOID
TR00952