Click here to make tpub.com your Home Page

Page Title: HORN DOES NOT OPERATE - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-1
VOLTAGE TEST
(1) Set multimeter to volts dc.
(2) Connect multimeter positive (+) lead to
ACCESS
P
circuit breaker CB6 where wire 1
ANEL
connects.
(3) Connect multimeter negative () lead to
known good ground.
(4) Connect negative battery cable (Para
8-44).
(a) If 24 vdc is not present, go to
Step 9 of this fault.
(b) If 24 vdc is present, repair wire 1
(Para 8-48).
(5) Disconnect negative battery cable
(Para 8-44).
SCREW
VOLTAGE TEST
WIRE 9
(1) Set multimeter to volts dc.
(2) Connect multimeter positive (+) lead to
circuit breaker CB6 where wire 9
connects.
(3) Connect multimeter negative () lead to
known good ground.
(4) Connect negative battery cable
(Para 8-44).
(a) If 24 vdc is not present, go to
Step 10 of this fault.
(b) If 24 vdc is present, replace circuit
breaker CB6 (Para 8-11).
CIRCUIT BREAKER CB6
WIRE 1
(5) Disconnect negative battery cable
TR00951
(Para 8-44).
2-55

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business