VOLTAGE TEST
P2-1
(1) Disconnect connector J2 from
connector P2.
(2) Set multimeter to volts dc.
(3) Connect multimeter positive lead (+) to
connector P2-1.
(4) Connect multimeter negative lead () to
CONNECTOR P2
known good ground.
(5) Connect negative battery cable to
negative side of battery (Para 8-44).
(a) If 24 vdc is present, go to Step 5 of
CONNECTOR
J
this fault.
2
(b) If 24 vdc is not present, go to
CONNECTOR P2
Step 8 of this fault.
(6) Disconnect negative battery cable from
negative side of battery (Para 8-44).
(7) Connect connector J2 to connector P2.
ACCESS
P
ANEL
VOLTAGE TEST
(1) Remove four screws and access panel.
(2) Set multimeter to volts dc.
(3) Connect multimeter positive lead (+) to
wire 9 at circuit breaker CB6.
(4) Connect multimeter negative lead () to
SCREW
known good ground.
(5) Connect negative battery cable to
negative side of battery (Para 8-44).
(a) If 24 vdc is present, go to Step 6 of
this fault.
(b) If 24 vdc is not present, go to
Step 7 of this fault.
(6) Disconnect negative battery cable from
negative side of battery (Para 8-44).
WIRE 9
CIRCUIT BREAKER CB6
TR01084
2-41
|