TM 10-3930-673-20-1
1. 24 VDC CIRCUITS DO NOT OPERATE (CONT).
2
KNOWN INFO
TEST OPTIONS
Battery connections OK.
Voltage test.
Is 24 vdc present at positive
STE/ICE-R #89.
POSSIBLE PROBLEMS
cable of battery?
REASON FOR QUESTION
Battery faulty.
Battery cable faulty.
If voltage is not present, 24 vdc
Wire 9 faulty.
circuits will not operate.
Connector P2 faulty.
Connector J2 faulty.
Circuit breaker CB6 faulty.
Ground faulty.
Service battery or
NO
replace battery
(Para 8-42).
YES
3
KNOWN INFO
TEST OPTIONS
Battery connections OK.
Voltage test.
Is 24 vdc present on positive
Battery OK.
STE/ICE-R #89.
battery cable at starter motor
POSSIBLE PROBLEMS
REASON FOR QUESTION
Battery cable faulty.
If voltage is not present, battery
Wire 9 faulty.
cable faulty.
Connector P2 faulty.
Connector J2 faulty.
Circuit breaker CB6 faulty.
Ground faulty.
Repair battery
NO
cable (Para 8-44).
YES
2-38
|