TM 10-3930-671-24
Control End
11.
Remove housing from vise and place on a clean
soft cloth to protect surface finish. Use a thin-
bladed screwdriver to pry retaining ring from
housing.
12.
Rotate spool and sleeve until pin is horizontal.
Push spool and sleeve assembly forward with
your thumbs just far enough to free seal gland
bushing from housing. Remove bushing.
13.
Remove quad ring seal from seal gland bushing.
14.
Use a thin-bladed screwdriver to pry dust seal
from seal gland bushing. Do not damage
bushing.
15.
Remove 2 bearing races and the needle thrust
bearing from spool and sleeve assembly.
16.
Remove spool and sleeve assembly from 14-
hole end of housing.
NOTE
Do not bind spool and sleeve in housing. Rotate
spool and sleeve assembly slowly when removing
from housing.
17.
Push pin from spool and sleeve assembly.
18.
Push spool partially from control end of sleeve,
then remove six (6) centering springs from spool
carefully by hand. Note their position in the unit
before they are removed.
19.
Push spool back through and out of sleeve.
Rotate spool slowly when removing from sleeve.
F-414
|