TM 10-3930-671-24
2.
Disc Contact Test
a)
Turn the analyzer function switch to the volt-drop
scale.
b)
On the starter solenoid, connect the positive (+)
analyzer cable to the solenoid "Battery" terminal
post and the negative (-) analyzer cable to the
solenoid motor terminal post.
c)
Turn ignition key switch to the START position
and crank the engine for 15 seconds, maximum.
Turn key switch OFF.
Diagnosis of results: While cranking the engine, a
voltmeter reading higher than 0.2 volts indicates
excessive
resistance
within
the
solenoid
switch
assembly. For example, the solenoid disc contact is
good if the voltage is 0.1-0.2 volts. The solenoid disc
contact is faulty if the voltage is 0.21-0.55 volts. Check
and clean or repair the solenoid switch contact disc and
terminals.
Starter Solenoid Volt Drop Test
1.
Turn the analyzer function switch to the volt-drop
scale.
2.
On the starter solenoid, connect the positive (+)
analyzer cable to the solenoid "Battery" terminal
post and the negative (-) analyzer cable to the
solenoid terminal post.
3.
Turn ignition key switch to the START position
and crank the engine for 15 seconds, maximum.
Check the voltmeter reading. Turn key switch
OFF.
F-308
|