TM 10-3930-671-24
g)
Check
starter
ground
circuit.
Connect
a
voltmeter from the frame (body) of the starter
motor to either a point on the engine flywheel
housing or the bolt that mounts the battery
negative cable to the ground connection on the
engine or frame. While cranking the engine, a
reading higher than 0.2 volts indicates excessive
resistance. Clean the starter mounting bolts and
flange.
Alternate - Connect the voltmeter from the frame of the
starter motor to the battery negative terminal post. While
cranking, a reading higher than 0.4-0.6 volts indicates
excessive resistance.
Clean starter mounting flange and bolts, check battery
negative cable for damage, and clean and tighten battery
cable connections.
F-305 (F-306 blank)
|