TESTING FOR REGULATOR VOLTAGE SETTING (22/30 Amp Systems)- This test requires the application of a 1/4 ohm
series resistance between alternator output terminal and output lead, to reduce charging current to approximately 8 to 10
amperes (Figure No. 12). Reducing current output will allow system voltage to rise to the operating level of the voltage
regulator.
FIGURE NO. 12.
The 1/4 ohm resistance may be incorporated in many commercial volt-ammeter assemblies (Figure No. 13.).
Switching the system knob from direct to 1/4 ohm is all that is required to establish series resistance. Separate 1/4 ohm
resistors are available and easily inserted in the system as shown in Figure No. 14.