TM 10-3930-671-24
(7)
Remove clamp (12) and pipe (13) from hydraulic sump (11).
(8)
Remove two screws (14) and hydraulic sump (11) from frame (15).
b.
Installation.
WARNING
Hydraulic fluid is slippery and can cause personal injury when spilled on a floor or other smooth
surface. Precautions should be taken to avoid any spillage and to clean up any spills when they
occur.
(1)
Install hydraulic sump (11) on frame (15) with two screws (14). Tighten screws 180-220 lb-in (20-25 Nm).
(2)
Install pipe (13) on hydraulic sump (11) with clamp (12).
(3)
Install screen (10) and hydraulic sump cover (3) on hydraulic sump (11) with seal (9) and clamp (8).
(4)
Install hose (7) on hydraulic sump cover (3) with clamp (6).
(5)
Apply sealing compound to threads of fitting (5).
(6)
Install hose (4) on fitting (5).
(7)
Install breather cap (2) and dipstick (1) on hydraulic sump cover (3).
(8)
Replace hydraulic filter (Appendix F, Hydraulic Sump - Fluid and Filter Change, Section 10.1).
(9)
Fill hydraulic reservoir (Appendix F, Hydraulic Sump - Fluid and Filter Change, Section 10.1).
(10)
Connect batteries (Para 3-25).
END OF TASK
3-91
|