TM 10-3930-671-24
(2)
Installation.
(a)
Position hose (5) and seal (4) on main hydraulic pump (3) with two clamps (2) and four screws (1).
(b)
Tighten four screws (1) 325-425 lb-in (37-48 Nm).
b.
Threaded Connector Hose.
(1)
Removal. Remove fitting (1) and seal (2) from fitting (3). Discard seal.
(2)
Installation. Install fitting (1) and seal (2) on fitting (3).
3-85
|