| |
TM 9-2330-373-14 & P
Table 4-2. Operator Troubleshooting Procedures - CONT
Malfunction
Test or Inspection
Corrective Action
TRANSAXLE (CONT)
17.
TRANSAXLE OVERHEATS.
Step 1.
Check transaxle fluid level (Para 3-11 [a]).
If fluid level is below lower arrow mark, add fluid (Para 3-11 [b]).
If fluid level is OK, notify unit maintenance.
ELECTRICAL SYSTEM
18.
ENGINE WILL NOT CRANK.
Step 1.
Check that system energizes when master electrical switch is turned to ON (Para 2-4 [b]) and
ignition key switch is turned to Run position (Para 2-4 [b]).
If system energizes, go to Step 2.
If system will not energize, notify unit maintenance.
Step 2.
Place direction control level in NEUTRAL position (Para 2-5 [a]).
If truck still does not start with direction control lever in NEUTRAL, notify unit maintenance.
If truck does start, problem solved.
19.
GAUGES DO NOT OPERATE.
Step 1.
Ensure master electrical switch is ON and ignition key switch is turned to Run position (Para 2-4 [b]).
If gauges do not operate, notify unit maintenance.
If gauges operate, problem solved.
4-7
|