TM 10-3930-669-34
15-7. MAST PRIMARY CYLINDER REPAIR (CONT).
(2)
Position drain pan under mast primary cylinder
(1).
(3)
Install two screws (2) in end of base (3).
WARNING
Use extreme care when removing or
installing lock wire. Lock wire is
under tension and can act as a
projectile when released suddenly.
Ensure proper eye protection is worn
to prevent injury to personnel.
NOTE
A bar may be used to rotate base left
or right until end of lock wire appears
in slot on cylinder. Lift up lock wire
end, rotate base and position lock
wire end on outside of cylinder,
rotating base until hook end of lock
wire is exposed in hole of base.
(4)
Remove lock wire (4) from base (3) and cylinder
(1). Discard lock wire.