TM 10-3930-669-34 (5) Turn  control  pump  housing  (1)  over  and remove    retaining    ring    (12)    and    gland bushing (13). (6) Remove  bearing  race  (14),  needle  thrust bearing  (15),  and  bearing  race  (16)  from spool and sleeve assembly (17). CAUTION Rotate   spool   and   sleeve   assembly slowly    when    removing    to    prevent damage that can occur from binding. (7) Remove  spool  and  sleeve  assembly  (17) from control pump housing (1). (8) Remove    preformed    packing    (18)    from spool  and  sleeve  assembly  (17).    Discard preformed packing. (9) Remove  two  preformed  packings  (19  and 20)   from   gland   bushing   (13).      Discard preformed packings. 12-17