TM 10-3930-669-34
8-8.
TORQUE CONVERTER REPLACEMENT/REPAIR (CONT).
c.
Cleaning/lnspection.
WARNING
Dry-cleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and
gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes;
and do not breathe vapors. Keep away from heat or flame. Never smoke when using
solvent; the
flashpoint for type I dry-cleaning solvent is 100°F (38°C) and for
type II is 138°F (50°C). Failure
to do so may result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent
contacts eyes, immediately flush eyes with water and get immediate medical attention.
CAUTION
Do not allow solvent or contaminants to enter torque converter; damage to torque
converter and transmission can result.
(1)
Clean all metal parts with dry-cleaning solvent and wiping rags.
(2)
Inspect all parts for breaks, cracks, burrs, sharp edges, and signs of overheating.
d.
Assembly. Install drive plate (4) and spacer
ring (8) on torque converter (3) with six washers
(7) and screws (6). Tighten screws (6) to 30 lb-ft
(41 Nm).
8-66
|