TM 10-3930-669-34 7-2. ALTERNATOR REPAIR (CONT). (22) Using  a  press,  remove  outer  bearing  (48)  from forging and field coil assembly (14). b. Cleaning/lnspection. WARNING Dry-cleaning solvent (P-D-680) is TOXIC and flammable.  Wear protective goggles and gloves; use only  in  a  well-ventilated  area;  avoid  contact  with  skin,  eyes,  and  clothes;  and  do  not  breathe vapors.  Keep away from heat or flame.  Never smoke when using solvent; the flashpoint for type I dry-cleaning solvent is 100°F (38°C) and for type II is 138°F (50°C).  Failure to do so may result in injury or death to personnel. If  personnel  become  dizzy  while  using  cleaning  solvent,  immediately  get  fresh  air  and  medical help.    If  solvent  contacts  skin  or  clothes,  flush  with  cold  water.    If  solvent  contacts  eyes, immediately flush eyes with water and get immediate medical attention. (1) Clean all metal parts with dry-cleaning solvent. (2) Do not allow dry-cleaning solvent to come in contact with rubber wire insulation. (3) Inspect all parts for breaks, cracks, burrs, and sharp edges. (4) Inspect rotor, refer to TM 9-2920-225-34. (5) Replace all damaged parts. 7-8