TM 10-3930-669-34
7-2.
ALTERNATOR REPAIR (CONT).
(22)
Using a press, remove outer bearing (48) from
forging and field coil assembly (14).
b.
Cleaning/lnspection.
WARNING
Dry-cleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use
only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe
vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type I
dry-cleaning solvent is 100°F (38°C) and for type II is 138°F (50°C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,
immediately flush eyes with water and get immediate medical attention.
(1)
Clean all metal parts with dry-cleaning solvent.
(2)
Do not allow dry-cleaning solvent to come in contact with rubber wire insulation.
(3)
Inspect all parts for breaks, cracks, burrs, and sharp edges.
(4)
Inspect rotor, refer to TM 9-2920-225-34.
(5)
Replace all damaged parts.
7-8
|