TM 10-3930-669-34 4-4.  INJECTION PUMP ADJUSTMENT (CONT). (5) With  the  aid  of  an  assistant  and  using  retainer,  rotate  pulley  (1)  slowly  clockwise  until  fuel  flow  is  reduced  to droplets. NOTE If the pointer is not pointing at right-hand mark on pulley, proceed to step (6). If the pointer is pointing at the right-hand mark on pulley, proceed to removal step (1). (6) Using retainer, rotate pulley (1) clockwise or counter-clockwise until pointer aligns with right-hand mark on pulley. 4-12