TM 10-3930-669-34 1-15.  ELECTRICAL SYSTEM (CONT). f. Instruments.  All instruments are equipped with individual lamps for illumination and share a common circuit for power of these lamps.  A common ground circuit is also shared for all instrument illumination.  All instrumentation is fully operable when the main power switch and engine switch are on. • Ammeter(1) receives voltage from the shunt and shares a common ground circuit with other instruments. • Hour meter (2) receives voltage from the fuse panel and shares a common ground circuit with other instruments. • Fuel level gauge (3) receives voltage from the fuse panel and is grounded at the sending unit mounted on the fuel tank. • Engine oil pressure gauge (4) receives voltage from the fuse panel and is grounded at the sending unit mounted on the engine. • Engine temperature gauge (5) receives voltage from the fuse panel and is grounded at the sending unit mounted on the engine. • Transmission oil temperature gauge (6) receives voltage from the fuse panel and is grounded at the sending unit mounted on the transmission. • Air restriction indicator gauge (7) indicates condition of air filter in inches of Hg. Red button is for resetting indicator. 1-16

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business