TM 10-3930-669-34 1-15.  ELECTRICAL SYSTEM (CONT). f. Instruments.  All instruments are equipped with individual lamps for illumination and share a common circuit for power of these lamps.  A common ground circuit is also shared for all instrument illumination.  All instrumentation is fully operable when the main power switch and engine switch are on. Ammeter(1) receives voltage from the shunt and shares a common ground circuit with other instruments. Hour meter (2) receives voltage from the fuse panel and shares a common ground circuit with other instruments. Fuel level gauge (3) receives voltage from the fuse panel and is grounded at the sending unit mounted on the fuel tank. Engine oil pressure gauge (4) receives voltage from the fuse panel and is grounded at the sending unit mounted on the engine. Engine temperature gauge (5) receives voltage from the fuse panel and is grounded at the sending unit mounted on the engine. Transmission oil temperature gauge (6) receives voltage from the fuse panel and is grounded at the sending unit mounted on the transmission. Air restriction indicator gauge (7) indicates condition of air filter in inches of Hg. Red button is for resetting indicator. 1-16