TM 10-3930-669-34 3-15.  ROCKER ARM AND PUSHROD REPLACEMENT/REPAIR (CONT). c.    Cleaning/lnspection. Dry-cleaning solvent (P-D-680) is TOXIC and flammable.  Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors.  Keep away from heat or flame.  Never smoke when using solvent; the flashpoint for type I dry-cleaning solvent is 100°F (38"C) and for type II is 138°F (50°C).  Failure to do so may result in injury or death to personnel. If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help.  If solvent contacts skin or clothes, flush with cold water.  If solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).  Use only with effective chip guarding and personal protective equipment (goggles/shield, gloves, etc.).   Failure to comply may result in injury or death to personnel. (1) Clean all metal parts with dry-cleaning solvent.  Dry with compressed air. (2) Inspect all parts for cracks or damage. (3) Replace all damaged parts. d. Assembly. Use  care  when  installing  snap  rings. Snap   rings   are   under   compression tension   and   can   act   as   projectiles when   released   which   could   cause severe injury. (1) Install screw (15) and nut (14) on two rocker arms (12). (2) Install two rocker arms (12), two washers (11), and two retaining rings (10) on rocker bracket (13). 3-84