TM 10-3930-669-34
3-12.
OIL PUMP REPLACEMENT (CONT).
b.
Cleaning/Inspection.
WARNING
Dry-cleaning solvent (P-D-680) is TOXIC and flammable. Wear protective
goggles and gloves; use only in a well-ventilated area; avoid contact with skin,
eyes, and clothes; and do not breathe vapors. Keep away from heat or flame.
Never smoke when using solvent; the flashpoint for type I dry-cleaning solvent
is 100°F (38°C) and for type II is 138°F (50°C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts skin or clothes, flush with cold water.
If solvent contacts eyes, immediately flush eyes with water and get immediate
medical attention.
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).
Use only with effective chip guarding and personal protective equipment
(goggles/shield, gloves, etc.). Failure to comply may result in injury or death to
personnel.
(1)
Clean all metal parts with dry-cleaning solvent. Dry with compressed air.
(2)
Inspect all parts for cracks or damage.
(3)
Replace all damaged parts.
c.
Installation.
(1)
Install oil pump (9) and baffle (19) on
crankcase (12) with two lock washers (18)
and screws (17). Tighten screws to 26 lb-
ft (35 N.m).
3-64
|