TM 10-3930-669-34 3-12. OIL PUMP REPLACEMENT (CONT). b. Cleaning/Inspection. WARNING Dry-cleaning   solvent   (P-D-680)   is   TOXIC   and   flammable.      Wear   protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors.  Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type I dry-cleaning solvent is 100°F (38°C) and for type II is 138°F (50°C).  Failure to do so may result in injury or death to personnel. If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help.  If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use   only   with   effective   chip   guarding   and   personal   protective   equipment (goggles/shield, gloves, etc.).  Failure to comply may result in injury or death to personnel. (1) Clean all metal parts with dry-cleaning solvent.  Dry with compressed air. (2) Inspect all parts for cracks or damage. (3) Replace all damaged parts. c. Installation. (1) Install   oil   pump   (9)   and   baffle   (19)   on crankcase (12) with two lock washers (18) and screws (17).  Tighten screws to 26 lb- ft (35 N.m). 3-64

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business